• Css Template Preview
  • Css Template Preview
  • Css Template Preview
  • Css Template Preview
   Kinco PLCs
   Expansion I/O Module
     PM323
     PM332
     PM331
     PM322
     PM321
   CPU Module
     CPU304
     CPU304EX
     CPU306EX
     CPU306
     CPU308
Partner
Product Location:Home - Products - PLC
   CPU306
CPU306
 
 
Technical Specification
Performance Indexes
CPU306
K306-24DT
K306-24AT
K306-24DR
K306-24AR
CPU
16-bit industrial
Execution Speed
Typical Bool instruction time: <0.5μS
Word operation time: <48μS
Arithmetic operation time for integers: <65μS
Arithmetic operation time for floating points: <150μS
DI Points
14XDC24V
DO Points
10XDC24V
10Xrelay
User Program Memory
FRAM, 8KB/about 1,200 steps
Program Backup
Permanent storage, without the need of battery
Memory Area
Variable storage area (V area): 4KB
System storage area (SM area): 300 bytes
Internal storage area (M area): 32 bytes
Data Retention Characteristic
Configure with the programming software: V area, C (counter) area
Retention Mode and Period
Adopt super capacitors and support a retention period of not less than 144 hours upon power failure under normal temperature.
Data Backup Characteristic
Perform backup operations VB3648~VB3902 according to user instructions, 255 bytes in total
Backup Mode and Time
FRAM, 255 bytes in total (writing operation for 10 billion times), permanent backup
Floating Points
Supported; the whole V area can be used for floating points
Programming Language Supported
Ladder Drawing (LD), Instruction List (IL)
Instruction Set
Basic instructions: 55; expansion instructions: 252
Password Protection
Yes
Max. I/O
Digital data: 88 in total (64 DI and 64 DO respectively);
Analog data: 16 in total (16 AI and 16 AO respectively)
 
Counter
128
Operation Mode of Counter
Addition, subtraction
Counter Range
-32768~32767
Counting Value Retention Function
Yes
Timer
128
1 ms time base: 4
10 ms time base: 16
100 ms time base: 108
High-speed Counter
 
6 high-speed counters
where, single-phase counters: 6, with a maximum frequency of 30 KHz
where, dual-phase counters: 4, with a maximum frequency of 20 KHz
Pulse Output
2, PTO (Pulse Train Output)/PWM (Pulse Width Modulation output);
Maximum output frequency: 20 KHz
Analog Potentiometer
2, 10-bit resolution, values corresponding to internal registers
Interruption Function
Timing interruption: 2, 1ms resolution;
Timer interruption: T2/T3, 1ms resolution;
Edge interruption: 4, rising edge or falling edge optional;
High-speed interruption, communication interruption
Real-time Clock
Yes, with an error not greater than 2 minutes/month under a temperature of 25°C
The user can use the software to set/read: year, month, day, hour, minute, second, week. Standby batteries are used to supply power for the real-time clock upon power failure. Under normal temperature, the accumulative retention period of the real-time clock upon power failure is up to 50,000 hours.
Number of Connectable Expansion Modules
4; regardless of types
COM Port
1, RS232 or RS485;
Supported working modes: Programming, Modbus-RTU (slave), Free protocol
Equipment Connected with COM Port
RS232/RS485: PC (for programming), third-party HMI panel, third-party serial communication equipment (for example, instruments, bar code reader, etc.)
Input Power Supply
DC24V±20%
AC85~265V
DC24V+/-20%
AC85~265V
Sensor Load Power Supply
DC24V, max. 500 mA
Dimensions (L*W*H)
125X114X70mm
 
 